Back to Search Start Over

Measurement of the Casimir force between parallel metallic surfaces.

Authors :
Bressi G
Carugno G
Onofrio R
Ruoso G
Source :
Physical review letters [Phys Rev Lett] 2002 Jan 28; Vol. 88 (4), pp. 041804. Date of Electronic Publication: 2002 Jan 15.
Publication Year :
2002

Abstract

We report on the measurement of the Casimir force between conducting surfaces in a parallel configuration. The force is exerted between a silicon cantilever coated with chromium and a similar rigid surface and is detected by looking at the shifts induced in the cantilever frequency when the latter is approached. The scaling of the force with the distance between the surfaces was tested in the 0.5-3.0 microm range, and the related force coefficient was determined at the 15% precision level.

Details

Language :
English
ISSN :
0031-9007
Volume :
88
Issue :
4
Database :
MEDLINE
Journal :
Physical review letters
Publication Type :
Academic Journal
Accession number :
11801108
Full Text :