Back to Search
Start Over
Simultaneous heart rate-motion sensor technique to estimate energy expenditure.
- Source :
-
Medicine and science in sports and exercise [Med Sci Sports Exerc] 2001 Dec; Vol. 33 (12), pp. 2118-23. - Publication Year :
- 2001
-
Abstract
- Purpose: Heart rate (HR) and motion sensors represent promising tools for physical activity (PA) assessment, as each provides an estimate of energy expenditure (EE). Although each has inherent limitations, the simultaneous use of HR and motion sensors may increase the accuracy of EE estimates. The primary purpose of this study was to establish the accuracy of predicting EE from the simultaneous HR-motion sensor technique. In addition, the accuracy of EE estimated by the simultaneous HR-motion sensor technique was compared to that of HR and motion sensors used independently.<br />Methods: Thirty participants (16 men: age, 33.1 +/- 12.2 yr; BMI, 26.1 +/- 0.7 kg.m(-2); and 14 women: age, 31.9 +/- 13.1 yr; BMI, 27.2 +/- 1.1 kg.m(-2) (mean +/- SD)) performed arm and leg work in the laboratory for the purpose of developing individualized HR-VO2 regression equations. Participants then performed physical tasks in a field setting for 15 min each. CSA accelerometers placed on the arm and leg were to discriminate between upper and lower body movement, and HR was then used to predict EE (METs) from the corresponding arm or leg laboratory regression equation. A hip-mounted CSA accelerometer and Yamax pedometer were also used to predict EE. Predicted values (METs) were compared to measured values (METs), obtained via a portable metabolic measurement system (Cosmed K4b(2)).<br />Results: The Yamax pedometer and the CSA accelerometer on the hip significantly underestimated the energy cost of selected physical activities, whereas HR alone significantly overestimated the energy cost of selected physical activities. The simultaneous HR-motion sensor technique showed the strongest relationship with VO(2) (R(2) = 0.81) and did not significantly over- or underpredict the energy cost (P = 0.341).<br />Conclusion: The simultaneous HR-motion sensor technique is a good predictor of EE during selected lifestyle activities, and allows researchers to more accurately quantify free-living PA.
- Subjects :
- Activities of Daily Living
Adult
Exercise Test
Female
Humans
Life Style
Male
Middle Aged
Monitoring, Ambulatory instrumentation
Predictive Value of Tests
Sensitivity and Specificity
Energy Metabolism physiology
Heart Rate physiology
Monitoring, Ambulatory methods
Movement physiology
Physical Exertion physiology
Subjects
Details
- Language :
- English
- ISSN :
- 0195-9131
- Volume :
- 33
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Medicine and science in sports and exercise
- Publication Type :
- Academic Journal
- Accession number :
- 11740308
- Full Text :
- https://doi.org/10.1097/00005768-200112000-00022