Back to Search Start Over

A side-by-side comparison of sampling methods for settled, indoor allergens.

Authors :
Mansour M
Lanphear BP
Hornung R
Khoury J
Bernstein DI
Menrath W
Decolongon J
Source :
Environmental research [Environ Res] 2001 Sep; Vol. 87 (1), pp. 37-46.
Publication Year :
2001

Abstract

Exposure to indoor allergens is associated with asthma, but there is no standardized sampling method for measuring allergens. We compared the association of measured allergen exposure and serum-specific IgE levels and the precision of three sampling methods (Cyclone, Mighty Mite, and Readivac II) to identify a standardized sampling method for indoor allergens. A random sample of 72 children, 5 to 17 years old, with doctor-diagnosed asthma who lived in the same residence >or=2 years were enrolled. Composite, side by side floor samples were obtained with all three methods. Dust allergen concentrations and serum-specific IgE levels were measured for Der f I, Fel d I, and Bla g I. Mean allergen concentration did not differ significantly by sampling method. Cat allergen was significantly correlated with serum-specific IgE for Cyclone (P=0.003) and Mighty Mite (P=0.008), but only marginally for Readivac II (P=0.07). Dust mite allergen was significantly correlated with serum-specific IgE for Readivac II (P=0.02) and Cyclone (P=0.038), but not for Mighty Mite (P=0.12). Cockroach allergen was not correlated with serum-specific IgE for any sampling method. In multiple linear regression, cat allergen was associated with serum-specific IgE for Cyclone (P=0.007) and Mighty Mite (P=0.02), but not for Readivac II (P=0.06). In contrast, dust mite allergen was marginally associated with serum-specific IgE for Readivac II (P=0.07), but not for Mighty Mite (P=0.64) or Cyclone (P=0.27). The Cyclone and Mighty Mite were more precise than Readivac II for cat allergen, but there was no difference for dust mite allergen (P>0.05). No single method is superior for measurement of indoor allergens. In general, cat allergen collected with the Cyclone was a better predictor of serum-specific IgE levels to Fel d I, whereas dust mite allergen collected with the Readivac II was a better predictor of serum-specific IgE levels to Der f I.<br /> (Copyright 2001 Academic Press.)

Details

Language :
English
ISSN :
0013-9351
Volume :
87
Issue :
1
Database :
MEDLINE
Journal :
Environmental research
Publication Type :
Academic Journal
Accession number :
11534963
Full Text :
https://doi.org/10.1006/enrs.2001.4284