Continuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass.
- Source :
-
British journal of anaesthesia [Br J Anaesth] 2001 Aug; Vol. 87 (2), pp. 223-8. - Publication Year :
- 2001
-
Abstract
- We measured the accuracy of the continuous intra-vascular blood-gas monitoring system (Paratrend 7, PT7) placed in the jugular venous bulb in 18 adult patients having cardiac or aortic surgery with hypothermic cardiopulmonary bypass (CPB). After induction of anaesthesia, a PT7 sensor was inserted through a 20-gauge venous catheter into the right jugular venous bulb. Blood samples were drawn from the venous catheter and measured with a blood gas analyser (BGA). Five to eight paired measurements using the PT7 and blood samples were made per patient, and bias and precision were calculated for each patient using the Bland-Altman method. The ranges for the blood sample measurements were: pH 7.12 to 7.59, PCO(2) 3.7 to 9.6 kPa, PO(2) 3.5 to 16.0 kPa, oxygen saturation 40 to 99%, bicarbonate 18.6 to 34.4 mmol l(-1), and base excess -7.8 to 12.5 mmol l(-1). Bias and precision values were 0.014/0.071 for pH, 0/0.90 kPa for PCO(2), and -0.16/1.18 kPa for PO(2). These values were comparable with those previously made on arterial blood. However, precision for oxygen saturation in each patient varied 2.3 to 23.6% (95% CI: 6.3 to 12.9%), which was unsatisfactory for clinical measurements. Deep hypothermia ( approximately 19.6 degrees C) and marked haemodilution ( approximately 13.5%) during CPB did not influence the reliability of the PT7 sensor. Thus, we concluded that continuous intra-jugular venous blood-gas monitoring is clinically feasible using the PT7 and may provide valuable information during CPB.
- Subjects :
- Adult
Aged
Blood Gas Analysis methods
Brain Ischemia etiology
Carbon Dioxide blood
Feasibility Studies
Female
Humans
Hydrogen-Ion Concentration
Hypothermia, Induced
Jugular Veins physiopathology
Male
Middle Aged
Monitoring, Intraoperative methods
Oxygen blood
Partial Pressure
Blood Gas Analysis instrumentation
Brain Ischemia diagnosis
Cardiopulmonary Bypass adverse effects
Monitoring, Intraoperative instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 0007-0912
- Volume :
- 87
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- British journal of anaesthesia
- Publication Type :
- Academic Journal
- Accession number :
- 11493493
- Full Text :
- https://doi.org/10.1093/bja/87.2.223