Back to Search
Start Over
Acute effects of haemodialysis on endothelial function and large artery elasticity.
- Source :
-
Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association [Nephrol Dial Transplant] 2001 Aug; Vol. 16 (8), pp. 1663-8. - Publication Year :
- 2001
-
Abstract
- Background: Disturbances of functional properties of large arteries contribute to increased cardiovascular morbidity and mortality in patients with end-stage renal disease. However, it is not clear whether haemodialysis per se acutely affects mechanical vessel wall properties or endothelial function.<br />Methods: Twenty-five chronic haemodialysis patients (mean+/-standard error of the mean (SEM): age 52+/-5 years; time on dialysis 63+/-7 months; blood pressure 132+/-4/72+/-2 mmHg) were studied before and immediately after a haemodialysis (HD) session using a polysulphone dialyser (ultrafiltration 1460+/-54 ml), as well as on the following day. Blood pressure was measured with an automatic sphygmomanometer and applanation tonometry. End-diastolic diameter and distension of the brachial and carotid arteries were measured by Doppler frequency analysis of vessel wall movements in M-mode using a multigate pulsed Doppler system and aortic pulse wave velocity (PWV) by an automatic device (Complior). Endothelial function was determined as brachial artery flow-mediated dilation (FMD) and compared with endothelium-independent nitroglycerine-induced dilation (NMD).<br />Results: FMD was 7.9+/-1.8% in patients before HD and did not change significantly after HD or in the dialysis-free intervall (6.7+/-2.1 and 7.1+/-2.0%, respectively; NS). The same was true for NMD and PWV (12.6+/-0.8 m/s before HD, 12.8+/-0.8 m/s after HD, and 11.9+/-0.7 m/s on the HD-free day). Carotid distensibility coefficients decreased significantly during HD (from 18.1+/-1.9 x 10(-3)/kPa to 16.7+/-2.2 x 10(-3)/kPa, P<0.05) and increased again on the HD-free day (19.8+/-2.4 x 10(-3)/kPa). However, when corrected for blood pressure by tonometry, isobaric carotid distensibility did not change significantly. Brachial artery distensibility also did not show significant acute changes.<br />Conclusions: Haemodialysis per se did not have a significant effect on endothelial function or large artery mechanical vessel wall properties in patients on maintenance dialysis therapy.
Details
- Language :
- English
- ISSN :
- 0931-0509
- Volume :
- 16
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
- Publication Type :
- Academic Journal
- Accession number :
- 11477171
- Full Text :
- https://doi.org/10.1093/ndt/16.8.1663