Back to Search
Start Over
Influence of a vital capacity maneuver on pulmonary gas exchange after cardiopulmonary bypass.
- Source :
-
Journal of cardiothoracic and vascular anesthesia [J Cardiothorac Vasc Anesth] 2001 Jun; Vol. 15 (3), pp. 336-40. - Publication Year :
- 2001
-
Abstract
- Objective: To investigate the effect of a single, vital capacity breath (vital capacity maneuver [VCM]), administered at the end of cardiopulmonary bypass (CPB), on pulmonary gas exchange in patients undergoing coronary artery bypass graft surgery.<br />Design: Prospective, randomized, double-blind study.<br />Setting: University-affiliated hospital.<br />Participants: Forty patients scheduled for elective coronary artery bypass graft surgery and early tracheal extubation.<br />Interventions: Patients were randomized to 1 of 2 groups. VCM patients received a VCM at the conclusion of CPB. Control patients received no VCM.<br />Measurements and Main Results: Intrapulmonary shunt (Q(S)/Q(T)), arterial oxygenation (PaO2), and alveolar-arterial oxygen gradients (P(A-a)O2) were measured after induction of anesthesia, CPB, intensive care unit (ICU) arrival, and extubation. The duration of postoperative intubation was recorded for each group. Q(S)/Q(T) increased significantly 30 minutes after CPB in the control group (15.7 +/- 1.8% to 27.4 +/- 2.6%; p = 0.01). In the VCM group, a small decrease in Q(S)/Q(T) occurred (16.1 +/- 2.0% to 14.9 +/- 2.0%). After ICU arrival and extubation, no significant difference in Q(S)/Q(T) existed between the 2 groups. With the exception of a higher P(A-a)O2 in the control group at induction of anesthesia, no differences in PaO2 or P(A-a)O2 were present between the 2 groups at any measurement interval. Patients who received a VCM were extubated earlier than the control group (6.5 +/- 2.1 hours v 9.4 +/- 4.2 hours; p = 0.01).<br />Conclusion: The use of a VCM prevented an increase in Q(S)/Q(T) from occurring in the operating room. Although a VCM did not influence pulmonary gas exchange in the ICU, its application in the operating room appears to exert a beneficial effect on tracheal extubation times after cardiac surgery.<br /> (Copyright 2001 by W.B. Saunders Company.)
Details
- Language :
- English
- ISSN :
- 1053-0770
- Volume :
- 15
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Journal of cardiothoracic and vascular anesthesia
- Publication Type :
- Academic Journal
- Accession number :
- 11426365
- Full Text :
- https://doi.org/10.1053/jcan.2001.23287