Back to Search
Start Over
Determination of procaterol in human plasma by gas chromatography/electron impact ionization mass spectrometry.
- Source :
-
Acta pharmacologica Sinica [Acta Pharmacol Sin] 2000 Jun; Vol. 21 (6), pp. 564-6. - Publication Year :
- 2000
-
Abstract
- Aim: To improve a gas chromatography/electron impact ionization mass spectrometry (GC/MS) method for determining the concentration of procaterol in human plasma.<br />Methods: GC/MS was developed with capillary column. Samples were extracted by liquid phase before derivated. Imipramine was used as an internal standard. The injector and GC/MS interface temperatures were set at 280 degrees C and 250 degrees C, respectively. The carrier gas (helium) was 0.8 mL.min-1, and injections were made in the pulse-splitless mode. The MS source and MS Quad temperature were 230 degrees C and 150 degrees C, respectively.<br />Results: The detection limit of plasma procaterol was 5 ng.L-1. The assay was linear over the range of 10-10,000 ng.L-1 with correlation coefficient of 0.9987. The coefficients of variation were less than 10% for procaterol detection at high, medium and low concentration levels (n = 5). The average recovery of the assay was 99.1% +/- 1.3%.<br />Conclusion: This assay was sensitive, precise, and accurate for evaluating the clinical pharmacokinetics of procaterol.
Details
- Language :
- English
- ISSN :
- 1671-4083
- Volume :
- 21
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Acta pharmacologica Sinica
- Publication Type :
- Academic Journal
- Accession number :
- 11360692