Back to Search Start Over

Transcranial Doppler sonography and internal jugular bulb saturation during hyperventilation in patients with fulminant hepatic failure.

Authors :
Strauss GI
Møller K
Holm S
Sperling B
Knudsen GM
Larsen FS
Source :
Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society [Liver Transpl] 2001 Apr; Vol. 7 (4), pp. 352-8.
Publication Year :
2001

Abstract

Mechanical hyperventilation is often used to postpone or ameliorate intracranial hypertension in patients with fulminant hepatic failure (FHF). Because such treatment may critically reduce cerebral blood flow (CBF), bedside techniques to monitor CBF are warranted. In this study, we evaluated the efficacy of transcranial Doppler (TCD) sonography of the middle cerebral artery (MCA) and internal jugular bulb saturation (svJO(2)) to determine relative changes in CBF during mechanical hyperventilation in 8 patients with FHF (median age, 40 years; range, 20 to 54 years). We found that TCD and svJO(2) decreased during hyperventilation in parallel with CBF, determined by the xenon 133 ((133)Xe) washout technique. Quantitatively, the TCD method was less accurate to determine carbon dioxide (CO(2)) reactivity compared with svJO(2) and the (133)Xe technique. This indicates a slight change in MCA diameter during hyperventilation. We conclude that TCD and svJO(2) monitoring may give valuable information on relative changes in CBF during hyperventilation. However, the TCD method appears less accurate for quantitative estimation of CO(2) reactivity in patients with FHF.

Details

Language :
English
ISSN :
1527-6465
Volume :
7
Issue :
4
Database :
MEDLINE
Journal :
Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society
Publication Type :
Academic Journal
Accession number :
11303296
Full Text :
https://doi.org/10.1053/jlts.2001.23075