High-performance liquid chromatographic analysis for the determination of buspirone analogue--mesmar in rat plasma.

Authors :
Kobylińska K
Cendrowska I
Kobylińska M
Barlińska M
Source :
Acta poloniae pharmaceutica [Acta Pol Pharm] 2000 Nov; Vol. 57 Suppl, pp. 65-7.
Publication Year :
2000

Abstract

A simple and selective analytical method for the determination of buspirone analogue--mesmar in rat plasma is described. The procedure involves liquid-liquid extraction followed by reversed-phase high-performance chromatographic analysis with UV detection at 245 nm. No endogenous compounds were found to interfere. The absolute extraction recovery from plasma samples was 76%. The linearity was assessed in the range 0.12-2.44 nmol/ml. Stability of mesmar during processing (autosampler) and in plasma was checked. This method proved suitable for pharmacokinetic studies following single oral dose in rats.

Details

Language :
English
ISSN :
0001-6837
Volume :
57 Suppl
Database :
MEDLINE
Journal :
Acta poloniae pharmaceutica
Publication Type :
Academic Journal
Accession number :