Back to Search Start Over

New normal limits for the paediatric electrocardiogram.

Authors :
Rijnbeek PR
Witsenburg M
Schrama E
Hess J
Kors JA
Source :
European heart journal [Eur Heart J] 2001 Apr; Vol. 22 (8), pp. 702-11.
Publication Year :
2001

Abstract

Aims: Previous studies that determined the normal limits for the paediatric ECG had their imperfections: ECGs were recorded at a relatively low sampling rate, ECG measurements were conducted manually, or normal limits were presented for only a limited set of parameters. The aim of this study was to establish an up-to-date and complete set of clinically relevant normal limits for the paediatric ECG.<br />Methods and Results: ECGs from 1912 healthy Dutch children (age 11 days to 16 years) were recorded at a sampling rate of 1200 Hz. The digitally stored ECGs were analysed using a well-validated ECG computer program. The normal limits of all clinically relevant ECG measurements were determined for nine age groups. Clinically significant differences were shown to exist, compared with previously established normal limits. Sex differences could be demonstrated for QRS duration and several amplitude measurements.<br />Conclusions: These new normal limits differ substantially from those commonly used and suggest that diagnostic criteria for the paediatric ECG should be adjusted.<br /> (Copyright 2001 The European Society of Cardiology.)

Details

Language :
English
ISSN :
0195-668X
Volume :
22
Issue :
8
Database :
MEDLINE
Journal :
European heart journal
Publication Type :
Academic Journal
Accession number :
11286528
Full Text :
https://doi.org/10.1053/euhj.2000.2399