Back to Search
Start Over
Comparison of 2-D turbo spin echo and 3-D gradient echo sequences for the detection of the trigeminal nerve and branches anatomy.
- Source :
-
European journal of radiology [Eur J Radiol] 2001 Jan; Vol. 37 (1), pp. 18-25. - Publication Year :
- 2001
-
Abstract
- The aim of this study was to assess the detectability of the trigeminal nerve and its branches using T1 weighted (w.) 3-D magnetization prepared rapid gradient echo (MP-RAGE), T2* w. 3D CISS and T2 w. 2-D turbo spin echo MR sequences. Thirty healthy volunteers were examined for this purpose using a 1.5 Tesla MR unit. The detectability of the trigeminal nerve and Gasser's Ganglion, i.e. structures that are surrounded by liquor was best using 3-D CISS. In the case of the ophthalmic, maxillary and mandibular nerves, the T1 w. 3-D MPRAGE was significantly better than T2* w. CISS and T2 w. 2-D turbo spin echo. The latter yielded the poorest results. We conclude that both high resolution T2* w. and T1 w. 3-D sequences are necessary in order to detect the liquor-surrounded trigeminal nerve and its soft tissue-surrounded branches. We would therefore recommend the inclusion of constructive interference in steady state (CISS) and MP-RAGE in a MR imaging protocol of the trigeminal nerve and its branches.
Details
- Language :
- English
- ISSN :
- 0720-048X
- Volume :
- 37
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- European journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 11274834
- Full Text :
- https://doi.org/10.1016/s0720-048x(00)00193-5