Back to Search Start Over

Sevoflurane (0.4 MAC) does not influence cerebral compliance in healthy individuals.

Authors :
Kolbitsch C
Lorenz HI
Hörmann C
Schocke M
Felber S
Zschiegner F
Pfeiffer PK
Benzer A
Source :
Journal of neurosurgical anesthesiology [J Neurosurg Anesthesiol] 2000 Oct; Vol. 12 (4), pp. 319-23.
Publication Year :
2000

Abstract

The use of sevoflurane is favored for its rapid onset and offset of anesthesia as well as good intraoperative titratability of the anesthetic. With regard to neuroanesthesia, the reported effects of sevoflurane on cerebral hemodynamics and cerebrospinal fluid dynamics are inconsistent. We used phase-contrast magnetic resonance imaging measurement of systolic cerebrospinal fluid peak velocity (CSFVPeak) to evaluate the effect of sevoflurane on cerebral compliance in healthy individuals. During administration of 0.4 MAC sevoflurane, systolic CSFVPeak in the aqueduct of Sylvius remained unchanged, thereby indicating unaffected cerebral compliance: (CSFVPeak baseline: -3.1 +/- 1.0 cm/s vs. sevoflurane: -3.0 +/- 1.2 cm/s). We conclude that low-dose administration of sevoflurane does not influence cerebral compliance in healthy individuals, but the influence of coexisting intracranial pathology or comedications on cerebral compliance requires further clinical investigation.

Details

Language :
English
ISSN :
0898-4921
Volume :
12
Issue :
4
Database :
MEDLINE
Journal :
Journal of neurosurgical anesthesiology
Publication Type :
Academic Journal
Accession number :
11147380
Full Text :
https://doi.org/10.1097/00008506-200010000-00004