Back to Search Start Over

Preoperative staging of non-small-cell lung cancer with positron-emission tomography.

Authors :
Pieterman RM
van Putten JW
Meuzelaar JJ
Mooyaart EL
Vaalburg W
Koëter GH
Fidler V
Pruim J
Groen HJ
Source :
The New England journal of medicine [N Engl J Med] 2000 Jul 27; Vol. 343 (4), pp. 254-61.
Publication Year :
2000

Abstract

Background: Determining the stage of non-small-cell lung cancer often requires multiple preoperative tests and invasive procedures. Whole-body positron-emission tomography (PET) may simplify and improve the evaluation of patients with this tumor.<br />Methods: We prospectively compared the ability of a standard approach to staging (computed tomography [CT], ultrasonography, bone scanning, and, when indicated, needle biopsies) and one involving PET to detect metastases in mediastinal lymph nodes and at distant sites in 102 patients with resectable non-small-cell lung cancer. The presence of mediastinal metastatic disease was confirmed histopathologically. Distant metastases that were detected by PET were further evaluated by standard imaging tests and biopsies. Patients were followed postoperatively for six months by standard methods to detect occult metastases. Logistic-regression analysis was used to evaluate the ability of PET and CT to identify malignant mediastinal lymph nodes.<br />Results: The sensitivity and specificity of PET for the detection of mediastinal metastases were 91 percent (95 percent confidence interval, 81 to 100 percent) and 86 percent (95 percent confidence interval, 78 to 94 percent), respectively. The corresponding values for CT were 75 percent (95 percent confidence interval, 60 to 90 percent) and 66 percent (95 percent confidence interval, 55 to 77 percent). When the results of PET and CT were adjusted for each other, only PET results were positively correlated with the histopathological findings in mediastinal lymph nodes (P<0.001). PET identified distant metastases that had not been found by standard methods in 11 of 102 patients. The sensitivity and specificity of PET for the detection of both mediastinal and distant metastatic disease were 95 percent (95 percent confidence interval, 88 to 100 percent) and 83 percent (95 percent confidence interval, 74 to 92 percent), respectively. The use of PET to identify the stage of the disease resulted in a different stage from the one determined by standard methods in 62 patients: the stage was lowered in 20 and raised in 42.<br />Conclusions: PET improves the rate of detection of local and distant metastases in patients with non-small-cell lung cancer.

Details

Language :
English
ISSN :
0028-4793
Volume :
343
Issue :
4
Database :
MEDLINE
Journal :
The New England journal of medicine
Publication Type :
Academic Journal
Accession number :
10911007
Full Text :
https://doi.org/10.1056/NEJM200007273430404