Back to Search
Start Over
TTCA measurements in biomonitoring of low-level exposure to carbon disulphide.
- Source :
-
International archives of occupational and environmental health [Int Arch Occup Environ Health] 2000 May; Vol. 73 (4), pp. 263-9. - Publication Year :
- 2000
-
Abstract
- Objectives: The biomonitoring of carbon disulphide exposure is currently performed by measuring the concentration of 2-thiothiazolidine-4-carboxylic acid (TTCA) in the urine of exposed workers.<br />Methods: In this study the effect of TTCA, which is found in some vegetables, on the biomonitoring of low-level carbon disulphide exposure was evaluated. In addition the upper reference limit (URL) of TTCA in the non-exposed Finnish population was estimated by analysing TTCA in urine samples from 116 people. The samples were collected at health centres all over Finland from people in employment and in the age group 24-64 years. The analytical measurements were made using a modern column-switching technique and the results were compared with those from the same samples using the extraction method generally in use and, until now, recommended for the determination of TTCA in urine.<br />Results: The results obtained with the two analytical methods correlated very well with each other (r = 0.9). The liquid-liquid extraction method gave results constantly about 3.5 micromol/l higher than the column-switching method. The results of this study also confirmed that many cruciferous vegetables (Cruciferae) contain endogenous TTCA (0.6-5.0 mg/kg), which is excreted unchanged in the urine. After a normal meal which included these vegetables, the TTCA concentration did not rise above the biomonitoring action level even if this was as low as 2 mmol/mol creatinine, but was easily above the URL of TTCA in the non-exposed population. The URL, calculated as the 95th percentile, was 0.3 mmol/mol creatinine.<br />Conclusion: The results showed that the extraction method was not sufficiently specific or sensitive when the TTCA concentrations were lower than 10 micromol/l. In contrast, the column-switching method seemed to give reliable results even at these low levels, which are the levels of interest in current practice.
Details
- Language :
- English
- ISSN :
- 0340-0131
- Volume :
- 73
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- International archives of occupational and environmental health
- Publication Type :
- Academic Journal
- Accession number :
- 10877032
- Full Text :
- https://doi.org/10.1007/s004200050426