Back to Search Start Over

Stimulation of Fracture Healing by Pacemaker in Rabbits.201S.

Authors :
Metaxas GM
Androulakis J
Tsiclakos C
Vezeridis M
Tsiftsis D
Source :
International surgery [Int Surg] 1975 May; Vol. 60 (5), pp. 294-6.
Publication Year :
1975

Abstract

An und-splaced fracture of each fibula was produced in 20 rabbits. Into the fracture of the right fibula, a cathode was inserted, which delivered 15 microamperes of galvanic current for more than one week. The source of current was 5v small transistor batteries which acted like a pacemaker. This stimulated healing of the fracture for 15 days. The left fibula fractures were used as controls. Both fibulae were studied roentgenographically and microscopically. This experiment suggested that galvanic current with a cathode placed in the fracture gap stimulated fracture healing.

Details

Language :
English
ISSN :
0020-8868
Volume :
60
Issue :
5
Database :
MEDLINE
Journal :
International surgery
Publication Type :
Academic Journal
Accession number :