Atrial fibrillation detection and R-wave synchronization by Metrix implantable atrial defibrillator: implications for long-term efficacy and safety. The Metrix Investigators.
- Source :
-
Circulation [Circulation] 1999 Mar 23; Vol. 99 (11), pp. 1446-51. - Publication Year :
- 1999
-
Abstract
- Background: The long-term efficacy of atrial fibrillation (AF) detection and R-wave synchronization are critical safety requirements for the development of an implantable atrial defibrillator (IAD) for treatment of AF.<br />Methods and Results: The long-term efficacy of the Metrix IAD for AF detection and R-wave synchronization was tested in 51 patients. The mean duration of follow-up was 259+/-138 days (72 to 613 days). AF detection tests were performed 2240 times during observed operation with 100% specificity and 92.3% sensitivity for differentiation between sinus rhythm and AF; 2219 episodes and their electrograms stored in the device during AF detection were analyzed. The positive predictive value of the AF detection algorithm was 97.4% (lower 95% confidence limit [CL], 94.5%) in the out-of-hospital setting. A total of 242 435 R waves were analyzed for R-wave synchronization. Of these, 49% were marked for synchronized shock delivery, 82% of sinus rhythm and 36% of AF R waves, respectively. All shock markers were properly synchronized and within the R wave (overall synchronization accuracy, 100%; lower 95% CL, 99.999%). Overall, 3719 shocks have been delivered via the IAD with no instance of unsynchronized shock delivery or any episode of proarrhythmia. The observed proarrhythmic risk was 0%, with an estimated maximum proarrhythmic risk of 0.084% per shock (95% upper CL).<br />Conclusions: The Metrix IAD can appropriately detect AF with a high specificity and sensitivity and reliably synchronize within a suitable R wave for shock delivery to minimize the risk of ventricular proarrhythmia.
- Subjects :
- Aged
Algorithms
Atrial Fibrillation physiopathology
Cohort Studies
Equipment Design
Female
Heart Conduction System physiopathology
Humans
Male
Middle Aged
Risk
Safety
Sensitivity and Specificity
Ventricular Fibrillation etiology
Ventricular Fibrillation prevention & control
Atrial Fibrillation diagnosis
Atrial Fibrillation surgery
Defibrillators, Implantable adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 0009-7322
- Volume :
- 99
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Circulation
- Publication Type :
- Academic Journal
- Accession number :
- 10086968
- Full Text :
- https://doi.org/10.1161/01.cir.99.11.1446