3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery.

Authors :
Coll DM
Uzzo RG
Herts BR
Davros WJ
Wirth SL
Novick AC
Source :
The Journal of urology [J Urol] 1999 Apr; Vol. 161 (4), pp. 1097-102.
Publication Year :
1999

Abstract

Purpose: Computerized tomography (CT) is the diagnostic and staging modality of choice for renal neoplasms. Existing imaging modalities are limited by a 2-dimensional (D) format. Recent advances in computer technology now allow the production of high quality 3-D images from helical CT. Nephron sparing surgery requires a detailed understanding of renal anatomy. Preoperative evaluation must delineate the relationship of the tumor to adjacent normal structures and demonstrate the vascular supply to the tumor for the surgeon to conserve as much normal parenchyma as possible. We propose that helical CT combined with 3-D volume rendering provides all of the information required for preoperative evaluation and intraoperative management of nephron sparing surgery cases. We prospectively evaluated the role of 3-D volume rendering CT in 60 patients undergoing nephron sparing surgery for renal cell carcinoma at the Cleveland Clinic Foundation.<br />Materials and Methods: Triphasic spiral CT was performed preoperatively in 60 consecutive patients undergoing nephron sparing surgery for renal neoplasms. A 3 to 5-minute videotape was prepared using volume rendering software which demonstrated the position of the kidney, location and depth of extension of the tumor(s), renal artery(ies) and vein(s), and relationship of the tumor to the collecting system. These videotapes were viewed by a radiologist and urologist in the operating room at surgery, and immediately correlated with surgical findings. Corresponding renal arteriograms of 19 patients were retrospectively compared to 3-D volume rendering CT and operative findings.<br />Results: A total of 97 renal masses were identified in 60 cases evaluated with 3-D volume rendering CT before nephron sparing surgery. There were no complications related to the 3-D protocol and 3-D rendering was successful in all patients. The number and location of lesions identified by 3-D volume rendering CT were accurate in all cases, while enhancement and diagnostic characteristics were consistent with pathological findings in 95 of 97 tumors (98%). Of 77 renal arteries identified at surgery 74 were detected by 3-D volume rendering CT (96%). Helical CT missed 3 small accessory arteries, including 1 in a cross fused ectopic kidney. All major venous branches and anomalies were identified, including 3 circumaortic left renal veins. Of 69 renal veins identified at surgery 64 were detected by 3-D volume rendering CT (93%). All 5 renal veins missed by CT were small, short, duplicated right branches of the main renal vein. Renal fusion and malrotation anomalies were correctly identified in all 4 patients.<br />Conclusions: The 3-D volume rendering CT accurately depicts the renal parenchymal and vascular anatomy in a format familiar to most surgeons. The data integrate essential information from angiography, venography, excretory urography and conventional 2-D CT into a single imaging modality, and can obviate the need for more invasive imaging. Additionally, the use of videotape in an intraoperative setting provides concise, accurate and immediate 3-D information to the surgeon, and it has become the preferred means of data display for these procedures at our center.

Details

Language :
English
ISSN :
0022-5347
Volume :
161
Issue :
4
Database :
MEDLINE
Journal :
The Journal of urology
Publication Type :
Academic Journal
Accession number :
10081846