- An upgrade of the edge rotation diagnostic system is achieved by increasing the number of viewing channels to 17 on J-TEXT tokamak. With the upgrade, the spatial resolution reaches 1 cm. The bulk plasma is used as the calibration light source. And the toroidal velocity profile of C V (carbon V) at edge region is obtained by using a spatial deconvolution technique. The valid measurement region is at ρ = 0.6-0.9, corresponding to the emitting region of C V. The preliminary experimental results express that the velocity of plasma may have a zero point near ρ = 0.85. [ABSTRACT FROM AUTHOR]