Back to Search
Start Over
Thermodynamics and separation factor of uranium from lanthanum in liquid eutectic gallium-indium alloy/molten salt system.
- Source :
-
Electrochimica Acta . Nov2014, Vol. 145, p81-85. 5p. - Publication Year :
- 2014
-
Abstract
- This work presents the electrochemical study of lanthanum and uranium compounds in fused 3LiCl-2KCl eutectic vs . Cl − /Cl 2 reference electrode in the temperature range 723–823 K on liquid gallium-indium eutectic alloy. Thermodynamics and the activity coefficients of lanthanum and uranium were studied. The separation factor of uranium from lanthanum on gallium-indium eutectic alloy was determined. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00134686
- Volume :
- 145
- Database :
- Academic Search Index
- Journal :
- Electrochimica Acta
- Publication Type :
- Academic Journal
- Accession number :
- 98666778
- Full Text :
- https://doi.org/10.1016/j.electacta.2014.08.081