Back to Search Start Over

Influence of system parameters on the hysteresis characteristics of a horizontal Rijke tube.

Authors :
Gopalakrishnan, E. A.
Sujith, R. I.
Source :
International Journal of Spray & Combustion Dynamics. Sep2014, Vol. 6 Issue 3, p293-316. 24p.
Publication Year :
2014

Abstract

The influence of system parameters such as heater power, heater location and mass flow rate on the hysteresis characteristics of a horizontal Rijke tube is presented in this paper. It is observed that a hysteresis zone is present for all the mass flow rates considered in the present study. A power law relation is established between the non-dimensional hysteresis width and the Strouhal number, defined as the ratio between convective time scale and acoustic time scale. The transition to instability in a horizontal Rijke tube is found to be subcritical in all the experiments performed in this study. When heater location is chosen as the control parameter, period-2 oscillations are found for specific values of mass flow rate and heater power. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17568277
Volume :
6
Issue :
3
Database :
Academic Search Index
Journal :
International Journal of Spray & Combustion Dynamics
Publication Type :
Academic Journal
Accession number :
98489298
Full Text :
https://doi.org/10.1260/1756-8277.6.3.293