Influence of system parameters on the hysteresis characteristics of a horizontal Rijke tube.
- Source :
-
International Journal of Spray & Combustion Dynamics . Sep2014, Vol. 6 Issue 3, p293-316. 24p. - Publication Year :
- 2014
-
Abstract
- The influence of system parameters such as heater power, heater location and mass flow rate on the hysteresis characteristics of a horizontal Rijke tube is presented in this paper. It is observed that a hysteresis zone is present for all the mass flow rates considered in the present study. A power law relation is established between the non-dimensional hysteresis width and the Strouhal number, defined as the ratio between convective time scale and acoustic time scale. The transition to instability in a horizontal Rijke tube is found to be subcritical in all the experiments performed in this study. When heater location is chosen as the control parameter, period-2 oscillations are found for specific values of mass flow rate and heater power. [ABSTRACT FROM AUTHOR]