Abstract

Process studies for Toroidal Field Structure (TF ST) system with a dedicated Auxiliary Cold Box (ACB-ST) have been conducted under 15 MA baseline, including plasma disruptions. ACB-ST consists of two heat exchangers immersed in the Liquid Helium (LHe) subcooler, which are placed at the inlet/outlet of a Supercritical Helium (SHe) cold circulator (centrifugal pump). Robustness of ACB-ST is a key to achieve the stability of TF coil operation since it provides the thermal barrier at the interface of the TF Winding Pack (WP) with ST. The paper discusses the control logic for the nominal plasma operating scenario and for Mitigation to regulate the dynamic heat loads on ST. In addition, the operation field of a cold circulator is described in the case of plasma disruptions. The required performance of heat exchangers in the ACB-ST is assessed based on the expected operating conditions. [ABSTRACT FROM AUTHOR]