Reflectometer density fluctuation measurements on DIII-D.
- Source :
-
Review of Scientific Instruments . Oct90, Vol. 61 Issue 10, p3016. 3p. - Publication Year :
- 1990
-
Abstract
- An O-mode, homodyne reflectometer system utilizing seven discrete channels spanning 15-75 GHz is in operation on DIII-D. A frequency-tunable X-mode system is also used to take fluctuation data from reflecting layers tying between those of the fixed frequency, O-mode system. In order to demonstrate the power and flexibility of this diagnostic, results are presented from several different plasma regimes, including L to H transitions, ELMS, and high beta operation. One specific example is that at all L-H transitions, high-frequency (≥ 50 kHz) fluctuations are dramatically suppressed in a localized region near the edge of the plasma on a timescale of ≈ 100 µs. [ABSTRACT FROM AUTHOR]