Back to Search Start Over

Image reconstructions of ECE and x-ray signals for high β plasmas on TFTR.

Authors :
Nagayama, Y.
Büchse, R.
Cavallo, A.
Fredrickson, E. D.
Janos, A.
McGuire, K. M.
Petravic, G. Kuo
Sule, C.
Taylor, G.
Source :
Review of Scientific Instruments. Oct90, Vol. 61 Issue 10, p3265. 3p.
Publication Year :
1990

Abstract

Reconstruction techniques have been developed to obtain 2-D images of high β plasmas by taking advantage of the large toroidal rotation rate on TFTR. The Shafranov shift, which is large in high β plasmas, is taken into account in the reconstructions. A 2-D image of the electron temperature is reconstructed from the electron cyclotron emission with the assumption of rigid poloidal rotation. The soft x-ray tomography is performed using the Fourier-Bessel expansion technique from two x-ray cameras. The reconstruction techniques are tested numerically through the use of model islands. The image is reproduced from the source function with these techniques; however, the x-ray tomography without rotation using the two cameras gives unacceptable results. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00346748
Volume :
61
Issue :
10
Database :
Academic Search Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
9786557
Full Text :
https://doi.org/10.1063/1.1141609