Back to Search Start Over

Use of high-granularity position sensing to correct response non-uniformities of CdZnTe detectors.

Authors :
Bolotnikov, A. E.
Camarda, G. S.
Cui, Y.
De Geronimo, G.
Fried, J.
Hossain, A.
Lee, K.
Mahler, G.
Maritato, M.
Marshall, M.
Petryk, M.
Roy, U.
Vernon, E.
Yang, G.
James, R. B.
Source :
Applied Physics Letters. 6/30/2014, Vol. 104 Issue 26, p1-5. 5p. 1 Diagram, 2 Graphs.
Publication Year :
2014

Abstract

CdZnTe (CZT) is a promising medium for room-temperature gamma-ray detectors. However, the low production yield of acceptable quality crystals hampers the use of CZT detectors for gammaray spectroscopy. Significant efforts have been directed towards improving quality of CZT crystals to make them generally available for radiation detectors. Another way to address this problem is to implement detector designs that would allow for more accurate and predictable correction of the charge loss associated with crystal defects. In this work, we demonstrate that high-granularity position-sensitive detectors can significantly improve the performance of CZT detectors fabricated from CZT crystals with wider acceptance boundaries, leading to an increase of their availability and expected decrease in cost. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00036951
Volume :
104
Issue :
26
Database :
Academic Search Index
Journal :
Applied Physics Letters
Publication Type :
Academic Journal
Accession number :
96941030
Full Text :
https://doi.org/10.1063/1.4883402