Back to Search Start Over

Preconcentration based on paramagnetic microparticles for the separation of sarcosine using hydrophilic interaction liquid chromatography coupled with coulometric detection.

Authors :
Zitka, Ondrej
Heger, Zbynek
Kominkova, Marketa
Skalickova, Sylvie
Krizkova, Sona
Adam, Vojtech
Kizek, Rene
Source :
Journal of Separation Science. Mar2014, Vol. 37 Issue 5, p465-575. 11p.
Publication Year :
2014

Abstract

Sarcosine has been identified as a potential prostate cancer marker. To provide determination of this compound, a number of methods are developing. In this study, we optimized a method for its separation by hydrophilic interaction LC with electrochemical detection ( ED). Due to the fact that mobile phases commonly used for this type of separation altered the LODs measured by electrochemical detectors, we applied postcolumn dosing of buffer suitable for ED. The optimized conditions were mobile phase A acetonitrile, mobile phase B water in the ratio A/ B 70:30, with postcolumn addition of mobile phase C (200 mM phosphate buffer pH 9). The optimal mixing ratio was A + B/ C 1:1 with a flow rate of 0.80 mL/min (0.40 + 0.40 mL/min) and detection potential of 1000 mV. Due to the optimization of the parameters for effective separation, which had to meet the optimal parameters of ED, we reached a good resolution for separation also with a good LOD (100 nM). In addition, we successfully carried out sarcosine analysis bound on our modified paramagnetic microparticles with the ability to preconcentrate sarcosine isolated from artificial urine. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16159306
Volume :
37
Issue :
5
Database :
Academic Search Index
Journal :
Journal of Separation Science
Publication Type :
Academic Journal
Accession number :
94759178
Full Text :
https://doi.org/10.1002/jssc.201301188