Back to Search
Start Over
Catheter-Tissue Contact Force Determines Atrial Electrogram Characteristics Before and Lesion Efficacy After Antral Pulmonary Vein Isolation in Humans.
- Source :
-
Journal of Cardiovascular Electrophysiology . Feb2014, Vol. 25 Issue 2, p122-129. 8p. - Publication Year :
- 2014
-
Abstract
- Catheter-Tissue Contact Force Determines Atrial Electrogram Characteristics Introduction Electrogram (EGM) characteristics are used to infer catheter-tissue contact. We examined if (a) atrial EGM characteristics predicted CF and (b) compared the value of CF versus other surrogates for predicting lesion efficacy. Methods and Results Twelve paroxysmal AF patients underwent pulmonary vein isolation using radiofrequency (RF) ablation facilitated by a novel CF-sensing catheter. Operators were blinded to CF. EGM amplitude, width, and morphology were measured pre- and post-RF. At each RF site, average CF, force-time integral (FTI), impedance fall, time to impedance plateau, maximum power, catheter tip temperature, and total energy delivered were recorded. An effective lesion was defined based on previously validated EGM criteria for transmural lesions. There was a moderate correlation between CF and EGM amplitude (r = 0.19) and EGM width (r = −0.22). Pre-RF, EGM amplitude, and width had modest to poor discriminative capacity for identifying preablation CF (e.g., EGM amplitude identified CF>20 g with sensitivity and specificity of 67% and 60%, respectively). Preablation CF, FTI, and total energy delivered during RF were the only independent predictors of effective lesion formation. Neither pre-RF EGM amplitude/width nor power, temperature, and impedance changes during RF predicted effective lesion formation. An average CF >16 g or FTI >404 g*s had excellent sensitivity and specificity (>80%) for identifying an effective lesion. Conclusions EGM characteristics do not reliably predict either CF before the onset of RF, nor do they predict the likelihood of an effective lesion. CF parameters were superior to power, temperature, and impedance changes during RF in predicting lesion efficacy. [ABSTRACT FROM AUTHOR]
- Subjects :
- *PULMONARY veins
*ATRIAL fibrillation
*CATHETER ablation
*CHI-squared test
*CONFIDENCE intervals
*ELECTROCARDIOGRAPHY
*EPIDEMIOLOGY
*FISHER exact test
*LONGITUDINAL method
*REGRESSION analysis
*T-test (Statistics)
*U-statistics
*DATA analysis
*RECEIVER operating characteristic curves
*DATA analysis software
*DESCRIPTIVE statistics
*SURGERY
Subjects
Details
- Language :
- English
- ISSN :
- 10453873
- Volume :
- 25
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- Journal of Cardiovascular Electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 94397693
- Full Text :
- https://doi.org/10.1111/jce.12293