Back to Search Start Over

Ti2448 Pedicle Screw System Augmentation for Posterior Lumbar Interbody Fusion.

Authors :
Zheng Wang
Suochao Fu
Zi-xiang Wu
Yang Zhang
Wei Lei
Source :
Spine (03622436). 11/1/2013, Vol. 38 Issue 23, p2008-2015. 8p.
Publication Year :
2013

Abstract

Study Design. A finite element analysis was used. Objective. To evaluate the feasibility of using the Ti-24Nb-4Zr-7.9Sn (Ti2448) pedicle screw system to augment single-level posterior lumbar interbody fusion (PLIF). Summary of Background Data. The Ti-6AI-4V pedicle screw system increases the risk of adjacent disc degeneration and stress-shielding effect due to enormous rigidity. A titanium alloy with much lower elastic modulus, Ti2448, may help to resolve the complications. Methods. A finite element model of intact L3-S1 was established and then validated. Single-level PLIF at L4-L5 with or without a supplementary titanium-alloy pedicle screw system was simulated. A pure moment of 7.6 Nm and a 400 N preload was applied to the finite element model of PLIF, PLIF with the Ti-6AI-4V screw system, and PLIF with the Ti2448 screw system in flexion, extension, axial rotation, and lateral bending. Results. The axial displacement at the fusion level decreased to 64%, 72%, 84%, and 92% of screw-free status in flexion, extension, axial rotation, and lateral bending, respectively, after augmentation of the Ti2448 screw system, which was 1% to 3% lower than the performance of the Ti-6AI-4V system. The angular displacement at the fusion level with the Ti2448 system was similar to that of the Ti-6AI-4V system, only 2% lower in flexion. Compared with theTi-6AI-4V system, the Ti2448 system suppressed the increase of intradiscal pressures at the upper adjacent disc in all bending directions, but only in extension and axial rotation at the lower adjacent disc; the maximum stress experienced by cages and screws was higher in all bending directions when augmented with the Ti2448 system. Conclusion. Using the Ti2448 screw system is suggested for augmenting single-level PLIF because it induces less disc intradiscal pressure at adjacent levels and the stress-shielding effect at implant-bone surface with stabilization performance compared with the Ti-6AI-4V screw system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03622436
Volume :
38
Issue :
23
Database :
Academic Search Index
Journal :
Spine (03622436)
Publication Type :
Academic Journal
Accession number :
91941981
Full Text :
https://doi.org/10.1097/BRS.0b013e3182a76fec