Back to Search Start Over

Clinical Impact, Safety, and Efficacy of Single- versus Dual-Coil ICD Leads in MADIT-CRT.

Authors :
KUTYIFA, VALENTINA
HUTH RUWALD, ANNE‐CHRISTINE
AKTAS, MEHMET K.
JONS, CHRISTIAN
McNITT, SCOTT
POLONSKY, BRONISLAVA
GELLER, LASZLO
MERKELY, BELA
MOSS, ARTHUR J.
ZAREBA, WOJCIECH
BLOCH THOMSEN, POUL ERIK
Source :
Journal of Cardiovascular Electrophysiology. Nov2013, Vol. 24 Issue 11, p1246-1252. 7p. 5 Charts, 2 Graphs.
Publication Year :
2013

Abstract

Single- versus Dual-Coil ICD Leads Background Current data on efficacy, safety and impact on clinical outcome of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads are limited and contradictory. Methods Defibrillation threshold (DFT) at implantation and first shock efficacy were compared in patients implanted with single- versus dual-coil ICD leads in MADIT-CRT. The risk for atrial tachyarrhythmias and all-cause mortality were evaluated. Short- (< 30 days after the implantation) and long-term (throughout the entire study duration) complications were assessed. Results Patients with dual-coil ICD leads had significantly lower DFTs compared to patients with single-coil ICD leads (17.6 ± 5.8 J vs 19.4 ± 6.1 J, P < 0.001). First shock efficacy was similar among patients with dual and single-coil ICD leads (89.6% vs 92.3%, P = 1.00). When comparing patients with dual versus single-coil ICD leads, there was no difference in the risk of atrial tachyarrhythmias (HR = 1.57, 95% CI: 0.81-3.02, P = 0.18), or in the risk of all-cause mortality (HR = 1.10, 95% CI: 0.58-2.07, P = 0.77). Patients implanted with single- or dual-coil ICD lead had similar short and long-term complication rates (short-term HR = 0.96, 95% CI: 0.56-1.65, P = 0.88, long-term procedure-related HR = 0.99, 95% CI: 0.62-1.59, P = 1.00, long-term ICD lead related: HR = 1.2, 95% CI: 0.5-2.9, P = 0.68) during the mean follow-up of 3.3 years. Conclusions Patients with single-coil ICD leads have slightly higher DFTs compared to those with dual-coil leads, but the efficacy, safety, and clinical impact on atrial tachyarrhythmias, and mortality is similar. Implantation of single-coil ICD leads may be favorable in most patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10453873
Volume :
24
Issue :
11
Database :
Academic Search Index
Journal :
Journal of Cardiovascular Electrophysiology
Publication Type :
Academic Journal
Accession number :
91674026
Full Text :
https://doi.org/10.1111/jce.12219