Real-time analysis of low-concentration photovoltaic systems: A review towards development of sustainable energy technology.

Authors :
Yadav, Pankaj
Tripathi, Brijesh
Rathod, Siddharth
Kumar, Manoj
Source :
Renewable & Sustainable Energy Reviews. Dec2013, Vol. 28, p812-823. 12p.
Publication Year :
2013

Abstract

Abstract: This article explores the potential of 1kWP low-concentration photovoltaic (LCPV) system for commercial purposes. Real-time analysis of in-house developed LCPV system shows better performance than the flat panel PV systems. Under actual test conditions (ATC), the open-circuit voltage (V OC ) decreases with temperature coefficient of voltage ≈−0.061V/K. The dynamic resistance is found to have a positive coefficient of module temperature i.e., dr d /dT≈0.49Ω/K. The annual energy generation of 1kWP LCPV power plant is envisaged as 1747.2kWh/kWP while the annual average daily final yield, reference yield and array yield were 3.76, 5.09 and 4.29h/day, respectively. The annual average daily performance ratio and capacity factor are 72% and 14%, respectively. The annual average daily system losses and capture losses are 0.57 and 0.80h/day correspondingly. [Copyright &y& Elsevier]