Back to Search Start Over

Optimization of the electrostatic and magnetic field configuration in the MITICA accelerator.

Authors :
Chitarin, G.
Agostinetti, P.
de Esch, H.P.L.
Marcuzzi, D.
Marconato, N.
Sartori, E.
Serianni, G.
Sonato, P.
Veltri, P.
Zaccaria, P.
Source :
Fusion Engineering & Design. Oct2013, Vol. 88 Issue 6-8, p507-511. 5p.
Publication Year :
2013

Abstract

Abstract: MITICA (Megavolt ITER Injector Concept Advancement) is a test facility for the development of a full-size heating and current drive neutral beam injectors for the ITER Tokamak reactor. The optimized electrostatic and magnetic configuration has been defined by means of an iterative optimization involving all the physics and the engineering aspects. The acceleration grids have been designed considering optical performances and mechanical constraints related to embedded magnets, to cooling channels, to the grid stiffness and manufacturability. A combination of “local” vertical field and horizontal “long range” field has been found to be the most effective set-up for ion extraction, beam focusing and minimization and equalization of thermo-mechanical loads and minimal number of electrons exiting the accelerator. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
09203796
Volume :
88
Issue :
6-8
Database :
Academic Search Index
Journal :
Fusion Engineering & Design
Publication Type :
Academic Journal
Accession number :
90524182
Full Text :
https://doi.org/10.1016/j.fusengdes.2013.02.052