High Dose Gamma Irradiation of Lasers and p-i-n Photodiodes for HL-LHC Data Transmission Applications.
- Source :
-
IEEE Transactions on Nuclear Science . Jul2013 Part 1, Vol. 60 Issue 4, p2518-2524. 7p. - Publication Year :
- 2013
-
Abstract
- Lasers and photodiodes for high luminosity large Hadron collider (HL-LHC) data transmission applications were irradiated with a 1-Gy dose of ^60\Co gammas. No change was observed in the performance of the lasers tested, and an order of magnitude increase in the leakage current of the InGaAs photodiodes was measured. [ABSTRACT FROM AUTHOR]