Back to Search Start Over

FEM modelling of a coaxial three-electrode test cell for electrochemical impedance spectroscopy in lithium ion batteries.

Authors :
Klink, Stefan
Höche, Daniel
La Mantia, Fabio
Schuhmann, Wolfgang
Source :
Journal of Power Sources. Oct2013, Vol. 240, p273-280. 8p.
Publication Year :
2013

Abstract

Abstract: Electrochemical impedance spectroscopy for lithium ion batteries has recently gained increasing attention due to its ability of non-invasive evaluation of important electrochemical parameters. Commonly used three-electrode test cells, however, proved unreliable due to asymmetric current line distributions, causing severe distortions of impedance spectra. Finite element method (FEM) simulations can visualize these current lines at different frequencies and simulate impedance spectra at given geometries. By applying FEM simulations to a recently developed coaxial impedance test cell, limiting conditions for reliable impedance measurements could be identified. Using a reference electrode in coaxial position yields sufficiently reliable results as long as the electrode misalignment is small compared to the electrolyte thickness and edge effects are prevented. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
03787753
Volume :
240
Database :
Academic Search Index
Journal :
Journal of Power Sources
Publication Type :
Academic Journal
Accession number :
89307481
Full Text :
https://doi.org/10.1016/j.jpowsour.2013.03.186