Back to Search Start Over

Improved net-section criterion solution for pipes with off-centered local wall thinning defects.

Authors :
Peng, Jian
Zhou, Chang-Yu
Dai, Qiao
Xue, Ji-Lin
He, Xiao-Hua
Source :
International Journal of Pressure Vessels & Piping. May2013, Vol. 105-106, p69-78. 10p.
Publication Year :
2013

Abstract

Abstract: In this paper, based on the finite element (FE) simulation and the analytical net-section criterion (NSC) solution, the influences of the off-centered angle and the dimension of local wall thinning (LWT) on limit loads of pipes with LWT are systematically investigated. It is interesting that the off-centered angle commonly affects the limit load for all dimensions of LWT. Moreover, the axial length of LWT also plays an important role in the load capacity, which cannot be considered in the analytical NSC solution. In order to improve the prediction accuracy of the NSC analytical solution of pipes with the off-centered LWT, the effects of the off-centered angle and the axial length are considered together in the establishment of the improved NSC solution. It is confirmed by the statistical analysis that the prediction accuracy of the NSC solution can be significantly improved by addressing the effects of two factors together. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
03080161
Volume :
105-106
Database :
Academic Search Index
Journal :
International Journal of Pressure Vessels & Piping
Publication Type :
Academic Journal
Accession number :
89193910
Full Text :
https://doi.org/10.1016/j.ijpvp.2013.03.006