Abstract
- Abstract: This paper focuses on mechanical tests on the ITER correction coils (CC) and Feeder jacket 316L stainless steel material. During manufacture, the conductor will be compacted and spooled after cable insertion. Therefore, sample jackets were prepared under compaction in order to simulate the status of conductor during manufacturing. Yield strength (0.2% offset), ultimate tensile strength, Young''s modulus and elongation at failure shall be reported. The mechanical properties of materials were measured at 300K and low temperature (<7K). The cryogenic test results show that the present jackets have very high properties. It is concluded that the results meet the ITER requirement. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 09203796
- Volume :
- 88
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- Fusion Engineering & Design
- Publication Type :
- Academic Journal
- Accession number :
- 86057868
- Full Text :
- https://doi.org/10.1016/j.fusengdes.2013.01.089