Back to Search Start Over

Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens

Authors :
Sheppard, Amy L.
Shah, Sunil
Bhatt, Uday
Bhogal, Gurpreet
Wolffsohn, James S.
Source :
Journal of Cataract & Refractive Surgery. Mar2013, Vol. 39 Issue 3, p343-349. 7p.
Publication Year :
2013

Abstract

Purpose: To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting: Midland Eye Institute, Solihull, United Kingdom. Design: Cohort study. Methods: Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to −4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results: The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to −2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at −1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions: The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
08863350
Volume :
39
Issue :
3
Database :
Academic Search Index
Journal :
Journal of Cataract & Refractive Surgery
Publication Type :
Academic Journal
Accession number :
85875356
Full Text :
https://doi.org/10.1016/j.jcrs.2012.09.017