Abstract

Background: Cardiac allograft vasculopathy (CAV) is a major late complication in cardiac transplant recipients and has a relevant impact on outcome of these patients. Aims of this study: to compare, in cardiac transplant recipients patients, the diagnostic value of pressure/volume relationship (ESPVR) during dobutamine stress echocardiography (DSE) for coronary artery disease, assessed by Multislice Computed Tomography (MSCT), and by coronary angiography (CA). We also analyzed any possible relationship between ESPVR and the Health Related Quality of Life of the patients (HRQoL), evaluated by SF-36 questionnaire. Methods: 25 consecutive patients underwent DSE within 24 hours after MSCT coronary angiogram and then they underwent CA. The HRQoL questionnaire was administered to the patients in the settings of DSE. They were followed-up for 6 months. Results: DSE has a sensitivity in detecting CAV of 67%, specificity of 95%, positive predictive value of 67% and negative predictive value of 95%; DSE with ESPVR has a sensitivity of 100%, specificity of 95%, positive predictive value of 75%, negative predictive value of 100%; MSCT has a sensitivity of 100%; specificity of 82%; positive predictive value of 43%; negative predictive value of 100%. Htx recipients with a flat-biphasic ESPVR, although asymptomatic, perceived a worst HRQoL compared with the up-sloping ESPVR population, and this is statistically significant for the general health (p 0.0004), the vitality (p 0.0013) and the mental health (p 0.021) SF-36 subscale. Conclusions: Evaluation with DSE and ESPVR is accurate in the clinical control of heart transplant recipients reserving invasive evaluation only for patients with abnormal contractility indexes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14767120
Volume :
10
Issue :
1
Database :
Academic Search Index
Journal :
Cardiovascular Ultrasound
Publication Type :
Academic Journal
Accession number :
85713466
Full Text :
https://doi.org/10.1186/1476-7120-10-44