Back to Search Start Over

Minimum fluidization velocities for supercritical water fluidized bed within the range of 633–693K and 23–27MPa

Authors :
Lu, Youjun
Zhao, Liang
Han, Qiang
Wei, Liping
Zhang, Ximin
Guo, Liejin
Wei, Jinjia
Source :
International Journal of Multiphase Flow. Mar2013, Vol. 49, p78-82. 5p.
Publication Year :
2013

Abstract

Abstract: Supercritical water fluidized bed is a new reactor concept for biomass gasification. In this paper, an experimental study on the hydrodynamics of a supercritical water fluidized bed was conducted. The frictional pressure drops of a fixed bed and a fluidized bed were measured for a temperature ranging from 633 to 693K and pressure ranging from 23 to 27MPa. The results show that the Ergun formula for calculating the frictional pressure drop of a fixed bed can still be applied in supercritical water conditions. The average deviation between Ergun formula and experiment results is 13.3%. A predicting correlation for the minimum fluidization velocity in a supercritical water fluidized bed was obtained based on the experimental results of a fixed bed and the fluidized bed pressure drop. The average error between the correlation and experiment results was about 3.1%. The results in this paper are useful for the design of SCW fluidized bed. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
03019322
Volume :
49
Database :
Academic Search Index
Journal :
International Journal of Multiphase Flow
Publication Type :
Academic Journal
Accession number :
84366991