Back to Search Start Over

The CMS ECAL non-event data handling.

Authors :
Punz, Thomas
CMS Collaboration
Source :
AIP Conference Proceedings. Dec2012, Vol. 1504 Issue 1, p1005-1008. 4p. 2 Diagrams.
Publication Year :
2012

Abstract

The Electromagnetic Calorimeter of the CMS experiment at the LHC includes about 76000 lead tungstate (PbWO4) scintillating crystals. The detector properties must be continuously monitored in order to ensure the extreme stability and precision required. This leads to a very large volume of non-event data to be accessed continuously by shifters, experts, automatic monitoring tasks, detector configuration for trigger and data acquisition systems and offline data reconstruction programs. This paper describes the measurements taken by the Detector Control System, the calibrations, the data handling strategy and the workflow as well as the architecture of the configuration and conditions databases and the web interface to access the data. An overview is given on the experience with detector commissioning, which have allowed a system test in realistic run conditions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1504
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
84140485
Full Text :
https://doi.org/10.1063/1.4771867