Back to Search Start Over

Actinides AMS at CIRCE and 236U and Pu measurements of structural and environmental samples from in and around a mothballed nuclear power plant

Authors :
De Cesare, M.
Fifield, L.K.
Sabbarese, C.
Tims, S.G.
De Cesare, N.
D’Onofrio, A.
D’Arco, A.
Esposito, A.M.
Petraglia, A.
Roca, V.
Terrasi, F.
Source :
Nuclear Instruments & Methods in Physics Research Section B. Jan2013, Vol. 294, p152-159. 8p.
Publication Year :
2013

Abstract

Abstract: Accelerator mass spectrometry (AMS) is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and 239Pu. A new actinide line is in operation at the Center for Isotopic Research on Cultural and Environmental heritage (CIRCE) in Caserta, Italy. Using the actinide line a uranium mass sensitivity of around 4μg has been reached measuring with a 16-strip silicon detector, and a 239Pu background level of below 0.1fg has been obtained. In this work we also discuss preliminary results for environmental and structural samples from in and around the Garigliano nuclear power plant (GNPP), presently in the decommissioning phase. Measurements on environmental samples from the vicinity of the plant allow the assessment of contamination, if any, over the years. Measurements of structural samples from the plant are relevant to the optimization of the decommissioning program for the GNPP. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
0168583X
Volume :
294
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section B
Publication Type :
Academic Journal
Accession number :
83960919
Full Text :
https://doi.org/10.1016/j.nimb.2012.05.020