Back to Search
Start Over
Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites
- Source :
-
Dental Materials . Nov2012, Vol. 28 Issue 11, p1146-1153. 8p. - Publication Year :
- 2012
-
Abstract
- Abstract: Objectives: This study''s purpose was to measure and compare the degree of conversion (DC) and the amount of elutable substances from modern resin-based composites (RBCs) as function of polymerization time. One nano-hybrid RBC based on tricyclodecane-(TCD)-urethane (Venus® Diamond) and two conventionally formulated RBCs (TetricEvo Ceram®, Filtek™ Supreme XTE) were considered. Method: DC (n =5) was investigated in real time for 5min by Fourier transform infrared spectroscopy (ATR-FTIR) in a filling depth of 2mm at varied irradiation times (5, 10, 20, 40s). After storing the specimens in ethanol/water for 7 d at 37°C the eluates were analyzed by gas chromatography/mass spectrometry. Results were statistically analyzed using a multivariate analysis (α =0.05) an independent t-test (p <0.05) and a Pearson correlation analysis. Results: In all groups increasing curing time resulted in a significant increase in DC. For TetricEvo Ceram® a high significant inverse correlation was found between DC and the amount of eluted camphorquinone (CQ, Pearson correlation coefficient=−0.88), ethylene glycol dimethacrylate (EGDMA, −0.73), 4-N,N-dimethylaminobenzoic acid ethylester (DMABEE, −0.87), triethylene glycol dimethacrylate (TEGDMA, −0.68), Tinuvin P (−0.71) and bisphenol-A-polyetheylene glycol dimethacrylate (BisEMA, −0.84). Unexpectedly DC and the amount of eluted methyl acrylate (MAA) correlated directly (0.72). In the specimens of Venus® Diamond a significant inverse correlation was found between DC and the amount of eluted CQ (−0.69) and TEGDMA (−0.50), whereas in the specimen of Filtek™ Supreme XTE DC correlated with CQ (−0.96), EGDMA (−0.70), DMABEE (−0.87), TEGDMA (−0.92) and MAA (−0.92). Significance: This study demonstrated a strong inverse correlation between DC and elutable substances in RBCs. Both evaluation methods emphasis the importance of an adequate polymerization (20, 40s), since short curing-times (5, 10s) resulted in lower DC and higher amount of eluted substances with toxic potential. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 01095641
- Volume :
- 28
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- Dental Materials
- Publication Type :
- Academic Journal
- Accession number :
- 82063465
- Full Text :
- https://doi.org/10.1016/j.dental.2012.08.006