Back to Search Start Over

Strain rate sensitivity and activation volume of Cu/Ni metallic multilayer thin films measured via micropillar compression.

Authors :
Carpenter, J. S.
Misra, A.
Uchic, M. D.
Anderson, P. M.
Source :
Applied Physics Letters. 7/30/2012, Vol. 101 Issue 5, p051901. 4p. 1 Black and White Photograph, 2 Charts, 3 Graphs.
Publication Year :
2012

Abstract

Micropillar compression testing with repeated jumps in strain rate is used to circumvent inherent difficulties associated with nanoindentation and tensile testing of free-standing films. Application to sputtered 21 nm/21 nm Cu/Ni multilayer thin films with a cube-on-cube texture reveals an average strain rate sensitivity (m = 0.014) and activation volume (V = 17 b3), comparable to nanocrystalline face-centered cubic metals. Yet, m increases by ∼50% and V decreases by 70% with increasing strain, opposite to trends reported for nanotwinned Cu. The large, strain-dependent shifts in m and V are dependent on the underlying misfit dislocation structure of Cu/Ni interfaces. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00036951
Volume :
101
Issue :
5
Database :
Academic Search Index
Journal :
Applied Physics Letters
Publication Type :
Academic Journal
Accession number :
78299184
Full Text :
https://doi.org/10.1063/1.4739521