Back to Search Start Over

A new ultra radiation hard cryogenic silicon tracker for heavy ion beams

Authors :
Casagrande, L.
Abreu, M.C.
Borer, K.
De Falco, A.
Dezillie, B.
Granata, V.
Heijne, E.
Hess, M.
Li, Z.
Lourenco, C.
Neves, A.
Niinikoski, T.O.
Palmieri, V.G.
Pes, B.
Ramalhete, P.
Rato Mendes, P.
Rosinsky, P.
Ruggiero, G.
Seixas, J.
Sonderegger, P.
Source :
Nuclear Instruments & Methods in Physics Research Section A. Feb2002, Vol. 478 Issue 1/2, p325. 5p.
Publication Year :
2002

Abstract

We have designed and built a new hodoscope for heavy ion beams consisting of two tracking stations equipped with silicon microstrip detectors operated at 130 K. Preliminary results from tests performed in the high intensity CERN-SPS Pb ion beam show that we were able to detect and identify each incoming ion up to a beam intensity of <f>∼107</f> ions/s. The beam profile could be monitored on-line with 50 <f>μ</f>m resolution. The detector performed satisfactory even after a dose of 90<f>±</f>40 Grad. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
01689002
Volume :
478
Issue :
1/2
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
7775677
Full Text :
https://doi.org/10.1016/S0168-9002(01)01819-8