Back to Search
Start Over
Iseult/INUMAC 11.7 T Conductor Production Status.
- Source :
-
IEEE Transactions on Applied Superconductivity . Jun2012, Vol. 22 Issue 3, p6001104-6001104. 4p. - Publication Year :
- 2012
-
Abstract
- The Iseult/INUMAC 11.7 T MRI magnet uses NbTi conductors larger than those typically used in conventional MRI magnets. The principal conductors are the main coil one, producing the magnetic field of 11.7 T and the conductor of the shielding coil that limits the fringe field. Both conductors are being produced by Luvata Waterbury Inc. The main coil conductor is a Rutherford cable in a copper channel (160 km) and carries 1500 A at 12 T and 2.8 K (2727 A at 9.5 T and 4.2 K). The shielding coil conductor is a wire in channel (60 km) and carries 2100 A at 5 T and 4.2 K. The conductor shape must be very precise with reproducible dimensions (tolerances below 15 microns) to enable good magnetic field homogeneity. They must also simultaneously exhibit a low electrical resistance (20 \mu\Omega/m at 10 K and 12 T) and a high mechanical strength (\sigma0.2\%>250\ MPa). Conductors of this industrial production are characterized by mechanical, electrical and geometrical measurements. [ABSTRACT FROM PUBLISHER]
Details
- Language :
- English
- ISSN :
- 10518223
- Volume :
- 22
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Applied Superconductivity
- Publication Type :
- Academic Journal
- Accession number :
- 76519715
- Full Text :
- https://doi.org/10.1109/TASC.2011.2180289