Back to Search Start Over

Performances of single and two-stage pulse tube cryocoolers under different vacuum levels with and without thermal radiation shields.

Authors :
Kasthurirengan, Srinivasan
Behera, Upendra
Nadig, D. S.
Krishnamoorthy, V.
Source :
AIP Conference Proceedings. 6/8/2012, Vol. 1434 Issue 1, p1632-1639. 8p. 2 Diagrams, 1 Chart, 6 Graphs.
Publication Year :
2012

Abstract

Single and two-stage Pulse Tube Cryocoolers (PTC) have been designed, fabricated and experimentally studied. The single stage PTC reaches a no-load temperature of ~ 29 K at its cold end, the two-stage PTC reaches ~ 2.9 K in its second stage cold end and ~ 60 K in its first stage cold end. The two-stage Pulse Tube Cryocooler provides a cooling power of ~ 250 mW at 4.2 K. The single stage system uses stainless steel meshes along with Pb granules as its regenerator materials, while the two-stage PTC uses combinations of Pb along with Er3Ni / HoCu2 as the second stage regenerator materials. Normally, the above systems are insulated by thermal radiation shields and mounted inside a vacuum chamber which is maintained at high vacuum. To evaluate the performance of these systems in the possible conditions of loss of vacuum with and without radiation shields, experimental studies have been performed. The heat-in-leak under such severe conditions has been estimated from the heat load characteristics of the respective stages. The experimental results are analyzed to obtain surface emissivities and effective thermal conductivities as a function of interspace pressure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1434
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
76488322
Full Text :
https://doi.org/10.1063/1.4707095