Back to Search Start Over

Soft x-ray tomoholography.

Authors :
Guehrs, Erik
Stadler, Andreas M.
Flewett, Sam
Fr¨ommel, Stefanie
Geilhufe, Jan
Pfau, Bastian
Rander, Torbj ¨ orn
Schaffert, Stefan
B¨ uldt, Georg
Eisebitt, Stefan
Source :
New Journal of Physics. Jan2012, Vol. 14 Issue 1, p1-8. 8p.
Publication Year :
2012

Abstract

We demonstrate an x-ray imaging method that combines Fourier transform holography with tomography ('tomoholography') for threedimensional (3D) microscopic imaging. A 3D image of a diatom shell with a spatial resolution of 140 nm is presented. The experiment is realized by using a small gold sphere as the reference wave source for holographic imaging. This setup allows us to rotate the sample and to collect a number of 2D projections for tomography. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13672630
Volume :
14
Issue :
1
Database :
Academic Search Index
Journal :
New Journal of Physics
Publication Type :
Academic Journal
Accession number :
72445359
Full Text :
https://doi.org/10.1088/1367-2630/14/1/013022