Back to Search Start Over

Multi-Mode Operation of Combined-Cycle Gas Turbines With Increasing Wind Penetration.

Authors :
Troy, Niamh
Flynn, Damian
OMalley, Mark
Source :
IEEE Transactions on Power Systems. Feb2012, Vol. 27 Issue 1, p484-492. 9p.
Publication Year :
2012

Abstract

As power systems evolve to incorporate greater penetrations of variable renewables, the demand for flexibility within the system is increased. Combined-cycle gas turbines are traditionally considered as relatively inflexible units, but those which incorporate a steam bypass stack are capable of open-cycle operation. Facilitating these units to also operate in open-cycle mode can benefit the power system via improved system reliability, while reducing the production needed from dedicated peaking units. The utilization of the multi-mode functionality is shown to be dependent on the flexibility inherent in the system and the manner in which the system is operated. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
08858950
Volume :
27
Issue :
1
Database :
Academic Search Index
Journal :
IEEE Transactions on Power Systems
Publication Type :
Academic Journal
Accession number :
71539165
Full Text :
https://doi.org/10.1109/TPWRS.2011.2163649