Back to Search Start Over

ESTUDIO DEL EFECTO DE LA MAGNETIZACIÓN EN LA FIABILIDAD DE LA OPERACIÓN DEL GENERADOR DE VAPOR DE LA EMPRESA MIELERA SIBONEY.

Authors :
de Lourdes de la Cruz Aragoneses, María
García, Martha Nápoles
Martín, Abdel Rivera
Source :
Centro Azúcar. jul-sep2008, Vol. 35 Issue 3, p1-7. 7p. 4 Charts.
Publication Year :
2008

Abstract

In this paper these random variables are analyzing : Failure time, the time between failures and number of failures in order to obtain their random laws as well as to evaluate economic and magnetic effects in inlet water for operating boiler. Failures classification is done . Failure time and the time between failures follow an exponential function. Economic benefits are determining with an 1.13 $ / h of saving and 83.08 % of decreasing in repaired costs are reported, this result confirms the effectiveness of magnetic treatment in inlet water to boiler. [ABSTRACT FROM AUTHOR]

Details

Language :
Spanish
ISSN :
02535777
Volume :
35
Issue :
3
Database :
Academic Search Index
Journal :
Centro Azúcar
Publication Type :
Academic Journal
Accession number :
69826497