Monte Carlo study of a 3D Compton imaging device with GEANT4

Authors :
Lenti, M.
Veltri, M.
Source :
Nuclear Instruments & Methods in Physics Research Section A. Oct2011, Vol. 654 Issue 1, p560-568. 9p.
Publication Year :
2011

Abstract

Abstract: In this paper we investigate, with a detailed Monte Carlo simulation based on Geant4, the novel approach of Lenti (2008) to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used to illuminate the object to be imaged and the photons Compton scattered are detected by means of a surrounding germanium strip detector. The impact position and the energy of the photons are measured with high precision and the scattering position along the beam axis is calculated. We study as an application of this technique the case of brain imaging but the results can be applied as well to situations where a lighter object, with localized variations of density, is embedded in a denser container. We report here the attainable sensitivity in the detection of density variations as a function of the beam energy, the depth inside the object and size and density of the inclusions. Using a 600keV gamma beam, for an inclusion with a density increase of 30% with respect to the surrounding tissue and thickness along the beam of 5mm, we obtain at midbrain position a resolution of about 2mm and a contrast of 12%. In addition the simulation indicates that for the same gamma beam energy a complete brain scan would result in an effective dose of about 1mSv. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
01689002
Volume :
654
Issue :
1
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
65869880
Full Text :
https://doi.org/10.1016/j.nima.2011.06.060