Back to Search Start Over

An active imaging digital image correlation method for deformation measurement insensitive to ambient light

Authors :
Pan, Bing
Wu, Dafang
Xia, Yong
Source :
Optics & Laser Technology. Feb2012, Vol. 44 Issue 1, p204-209. 6p.
Publication Year :
2012

Abstract

Abstract: Varying ambient light may cause serious decorrelation effect in the images recorded using an ordinary optical imaging device, which prevent digital image correlation (DIC) from out-of-laboratory use. In this paper, we describe an easy-to-implement yet effective monochromatic light illuminated active imaging DIC method for obtaining high-quality images suitable for high fidelity deformation measurement. Experiments reveal that the active imaging DIC method is able to provide reliable and accurate measurements even though the ambient light has been seriously changed. The active imaging DIC method is promising for developing flexible and robust in situ deformation measurement systems for use in both laboratory and non-laboratory environment, and should therefore have more potential engineering applications. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
00303992
Volume :
44
Issue :
1
Database :
Academic Search Index
Journal :
Optics & Laser Technology
Publication Type :
Academic Journal
Accession number :
63986865
Full Text :
https://doi.org/10.1016/j.optlastec.2011.06.019