Waveguide Measurements of the Permittivity and Permeability at Temperatures of up to 1000 ^\circ\C.

Authors :
Larsson, Christer
Sjoberg, Daniel
Elmkvist, Lisa
Source :
IEEE Transactions on Instrumentation & Measurement. Jul2011, Vol. 60 Issue 8, p2872-2880. 9p.
Publication Year :
2011

Abstract

This paper describes a method to measure the permittivity and permeability at temperatures from room temperature up to 1000 ^\circ\C using a single rectangular waveguide. The hardware design of the setup that can handle these temperatures, and the procedure that is required to correct the thermal expansion is developed. This includes the sample displacement, the displacement of the calibration reference planes, the thermal expansion of the waveguide, and the gap between the sample and the waveguide wall. Measurements on Macor and NiZn ferrite samples are performed in order to evaluate the performance of the setup and the procedure that is used to determine the permittivity and permeability from the measured S-parameters. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
00189456
Volume :
60
Issue :
8
Database :
Academic Search Index
Journal :
IEEE Transactions on Instrumentation & Measurement
Publication Type :
Academic Journal
Accession number :
62967830
Full Text :
https://doi.org/10.1109/TIM.2011.2122150